<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://patholines.org/index.php?action=history&amp;feed=atom&amp;title=Low_blood_glucose</id>
	<title>Low blood glucose - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://patholines.org/index.php?action=history&amp;feed=atom&amp;title=Low_blood_glucose"/>
	<link rel="alternate" type="text/html" href="https://patholines.org/index.php?title=Low_blood_glucose&amp;action=history"/>
	<updated>2026-08-20T16:10:01Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.2</generator>
	<entry>
		<id>https://patholines.org/index.php?title=Low_blood_glucose&amp;diff=3092&amp;oldid=prev</id>
		<title>Mikael Häggström: If</title>
		<link rel="alternate" type="text/html" href="https://patholines.org/index.php?title=Low_blood_glucose&amp;diff=3092&amp;oldid=prev"/>
		<updated>2021-01-28T16:48:37Z</updated>

		<summary type="html">&lt;p&gt;If&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 12:48, 28 January 2021&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l6&quot;&gt;Line 6:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 6:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*2 patient identifiers (for example name and date of birth).&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*2 patient identifiers (for example name and date of birth).&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Any symptoms of hypoglycemia if known.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Any symptoms of hypoglycemia if known.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Time of collection and time of collection by the lab. If delayed more than 4 hours, it is generally a false low blood glucose if there is no report of hypoglycemia signs, and the lab can generally be told to hold the release of the result, and the absence of centrifugation at the time of collection can be confirmed with the blood drawing site the following day. For each hour before centrifugation, plasma glucose decreases by approximately 0.3 mmol/L, 6 mg/dL or 7% per hour, and serum glucose by approximately 0.25 mmol/L, 4.5 mg/dL or 5% per hour.&amp;lt;ref&amp;gt;{{cite web|url=https://acutecaretesting.org/en/journal-scans/preanalytic-error-in-plasma-serum-glucose-measurement-examined|title=Preanalytic error in plasma/serum glucose measurement examined|author=Chris Higgins}} July 2019. In turn citing: Lippi G, Salvagno G, Lampus S et al. Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes. Clin Chem Lab Med 2018; 56: 2125-31&amp;lt;/ref&amp;gt;  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Time of collection and time of collection by the lab.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;:*&lt;/ins&gt;If delayed more than 4 hours, it is generally a false low blood glucose if there is no report of hypoglycemia signs, and the lab can generally be told to hold the release of the result, and the absence of centrifugation at the time of collection can be confirmed with the blood drawing site the following day. For each hour before centrifugation, plasma glucose decreases by approximately 0.3 mmol/L, 6 mg/dL or 7% per hour, and serum glucose by approximately 0.25 mmol/L, 4.5 mg/dL or 5% per hour.&amp;lt;ref&amp;gt;{{cite web|url=https://acutecaretesting.org/en/journal-scans/preanalytic-error-in-plasma-serum-glucose-measurement-examined|title=Preanalytic error in plasma/serum glucose measurement examined|author=Chris Higgins}} July 2019. In turn citing: Lippi G, Salvagno G, Lampus S et al. Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes. Clin Chem Lab Med 2018; 56: 2125-31&amp;lt;/ref&amp;gt;  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;:*For test results not sent out due to pre-analytical errors, preferably contact the clinician currently in charge of the patient to:&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;::*Exclude the presence of any symptoms expected in the case of an actual deranged value.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;::*Inform about a cancelled test result, potentially with the need to take new samples.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{Bottom}}&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{Bottom}}&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Mikael Häggström</name></author>
	</entry>
	<entry>
		<id>https://patholines.org/index.php?title=Low_blood_glucose&amp;diff=3091&amp;oldid=prev</id>
		<title>Mikael Häggström: Started</title>
		<link rel="alternate" type="text/html" href="https://patholines.org/index.php?title=Low_blood_glucose&amp;diff=3091&amp;oldid=prev"/>
		<updated>2021-01-28T14:58:46Z</updated>

		<summary type="html">&lt;p&gt;Started&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{Top&lt;br /&gt;
|author1=[[User:Mikael Häggström|Mikael Häggström]]&lt;br /&gt;
|author2=&lt;br /&gt;
}}&lt;br /&gt;
If called after hours about a low blood glucose value, inquire about:&lt;br /&gt;
*2 patient identifiers (for example name and date of birth).&lt;br /&gt;
*Any symptoms of hypoglycemia if known.&lt;br /&gt;
*Time of collection and time of collection by the lab. If delayed more than 4 hours, it is generally a false low blood glucose if there is no report of hypoglycemia signs, and the lab can generally be told to hold the release of the result, and the absence of centrifugation at the time of collection can be confirmed with the blood drawing site the following day. For each hour before centrifugation, plasma glucose decreases by approximately 0.3 mmol/L, 6 mg/dL or 7% per hour, and serum glucose by approximately 0.25 mmol/L, 4.5 mg/dL or 5% per hour.&amp;lt;ref&amp;gt;{{cite web|url=https://acutecaretesting.org/en/journal-scans/preanalytic-error-in-plasma-serum-glucose-measurement-examined|title=Preanalytic error in plasma/serum glucose measurement examined|author=Chris Higgins}} July 2019. In turn citing: Lippi G, Salvagno G, Lampus S et al. Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes. Clin Chem Lab Med 2018; 56: 2125-31&amp;lt;/ref&amp;gt; &lt;br /&gt;
&lt;br /&gt;
{{Bottom}}&lt;/div&gt;</summary>
		<author><name>Mikael Häggström</name></author>
	</entry>
</feed>